Printed from acutecaretesting.org
Articles by Christopher P. Price
Showing articles by "Christopher P. Price"
Article
April 2004
Setting the record straight on shunt
The understanding and management of ventilation-perfusion (V/Q) relationships represents a cornerstone of intensive care unit (ICU) patient management.
The physiologic shunt calculation can reliably reflect the degree of gas exchange attributable to intrapulmonary disease or intracardiac shunting regardless of other ...
Blood gases/acid-base
Hemoglobins
Article
October 2003
Pulse oximetry vs. transcutaneous monitoring in neonates: practical aspects
Non-invasive monitoring of oxygenation has become a standard procedure in neonatal critical care. Both transcutaneous pO2 (tcpO2) monitors and pulse oximeters involve methodological and practical issues that should be known to those using these devices in infants.
tcpO2 measurements are influenced by skin thickness, ...
Neonatology
Hemoglobins
Article
October 2003
Benchmarking as part of competency testing
Like many hospitals throughout the world, the Princess Royal Hospital in Sussex, England has set up a quality assurance (QA) scheme to verify the competency of glucose-meter operators. Their scoring system, however is anything but typical.
Instead of relying solely on individual results, the system also uses...
Quality assurance
Point-of-care testing
Glucose
Article
Article
March 2003
Method comparison or procedure comparison?
With the increasing number of blood tests performed at the point of care (POC), it has become more and more important to perform method comparison studies, comparing new methods to the existing methods used in the laboratory (LAB). This is done primarily to ensure that uniform results are reported throughout the...
Quality assurance
Point-of-care testing
Preanalytical phase
Glucose
Lactate
Article
March 2003
Standardizing is the key to effective POCT
According to the Hvidovre Hospital, standardizing is a must
if POCT is to run optimally. In the first article of the series
"POCT setups for blood gas", acutecaretesting.org interviews
the Danish hospital on how they have successfully implemented
POCT.
Point-of-care testing
Information management
Process optimization
Glucose
Hemoglobins
Troponins
Article
May 2002
Transcutaneous carbon dioxide monitoring: Applications in the operating room
The intraoperative monitoring of the partial pressure of carbon dioxide in arterial blood (pCO2) is used to assess the adequacy of ventilation and guide clinical interventions.
Although end-tidal CO2 monitoring remains the most frequently used non-invasive technology in the intraoperative setting to provide a...
Blood gases/acid-base
Neonatology
Kidneys/fluids
Article
May 2001
Quality control of multi-profile blood gas testing
Whether performed by one "traditional" or several "point-of-care" devices, all Multi-Profile Blood Gas (MPBG) results must be accurate and precise if they are to be effective in managing critically ill patients.
Optimal analytical quality control of multi-profile blood gas analysis requires a good quality assurance...
Quality assurance
Article
January 2001
Hyperbilirubinemia and requirements to the determination of the concentration of bilirubin
60 % of all neonates develop jaundice during their first week of life and thereby run a risk of getting hyperbilirubinemia.
Although different approaches for establishing treatment criteria have been suggested, treatment of neonatal hyperbilirubinemia is usually still based on the measurement of total bilirubin...
Preanalytical phase
Bilirubin
Neonatology
Hemoglobins
