Printed from acutecaretesting.org
Articles by Craig M. Nelson
Showing articles by "Craig M. Nelson"
Article
January 2004
What is EQA
External Quality Assessment (EQA) in medical laboratories have evolved over the past 50 years to provide more sophisticated systems compared with the simple participants’ analytical performance evaluation of earlier years.
There are clear distinctions between the proficiency testing schemes and the evolved External...
Quality assurance
Article
January 2004
Transcutaneous monitoring of pO2 and pCO2 in neonates - a blessing or a burden?
Monitoring of blood gases is essential in neonatal intensive care. Traditionally arterial samples have been considered the gold standard, but in critically ill neonates physiological changes can happen within minutes to a degree endangering the newborn.
Clinicians can therefore not rely solely on intermittent...
Neonatology
Article
September 2003
Transcutaneous monitoring - a Danish approach
Danish neonatal intensive care units (NICUs) are known
throughout the world for practicing minimal handling. Because it is
non-invasive, transcutaneous monitoring of pO2
and pCO2 plays an important role in this
setup.
acutecaretesting.org has interviewed Professor Gorm
Greisen, MD, Dr. Med. Sci., and Head of the...
Neonatology
Article
April 2003
STAT testing in the future
Since the mid 1990's Point of Care Testing (POCT) has been viewed as a solution to a declared need for Short Turn Around Testing (STAT).
However, is it being utilized in a way that meets the needs of improving patient care and hospital quality assurance? What is STAT testing, why and how did it become POCT? How is...
Process optimization
Point-of-care testing
Information management
Glucose
Creatinine/urea
Article
February 2003
What is p50
p50 is a shorthand representation of hemoglobin-oxygen affinity. A lower p50 is protective in ambient hypoxemia, whereas increasing the p50 should be beneficial in hypoxia due to lung disease, anemia, and tissue ischemia.
Despite encouraging theoretical and experimental data, it is not yet established that...
Blood gases/acid-base
Hemoglobins
Article
December 2002
From hospitals to project organizations
If you think only private corporations can call themselves project organizations, think again. Hospitals around the world are increasingly seeing themselves as project organizations and relying on project groups to explore and implement new technologies.
Meanwhile, healthcare workers participating in these projects...
Process optimization
Point-of-care testing
Glucose
Article
November 2002
The role of training, competency assessment, and continuing education
In a 1999 study, the US Institute of Medicine (IOM) concluded that 44,000 to 98,000 hospitalized Americans die each year from preventable medical errors.
While the number of serious medical errors attributable to point of care (point-of-care testing, POCT) is not known, the testing environment (patient bedside) and...
Process optimization
Point-of-care testing
Glucose
Article
September 2002
A six sigma primer desc.
"Six Sigma" is the latest trend in quality management and is being widely implemented in business and industry today.
Six Sigma represents an evolution of Total Quality Management (TQM), providing a more quantitative framework for evaluating process performance and clearer goals for process improvement. The...
Quality assurance
Article
September 2002
U.S. quality assurance regulations for decentralized testing
In the U.S. all testing, including decentralized testing, is regulated according to the Clinical Laboratory Improvement Amendments of 1988 (CLIA'88). Congress passed CLIA'88 to ensure accurate, reliable, and timely test results regardless of test site.
These quality control, quality assurance, and proficiency tesing...
Quality assurance
Information management
Article
May 2002
Key elements in a successful pediatric laboratory
Children are not just small adults, and present unique challenges to the clinical laboratory. Blood specimens must be very small; for example, total blood volumes in a premature infant can be as small as 115 mL. Genetic diseases frequently must be detected in the newborn period. Reference values change with age....
Neonatology
Blood gases/acid-base
Point-of-care testing
Preanalytical phase
Glucose
Hemoglobins
