Printed from acutecaretesting.org
Articles by Daniel R Vanhee
Showing articles by "Daniel R Vanhee"
Article
July 2011
Central venous blood gas analysis
Blood gas analysis (BGA) is a laboratory and point-of-care test routinely used to assess acid-base status along with adequacy of ventilation and oxygenation among predominantly critically/acutely ill patients.
The ”gold standard” sample for BGA is arterial blood collected anaerobically by needle puncture of an artery ...
Blood gases/acid-base
Lactate
Hemoglobins
Article
June 2011
How to manage sepsis in the Emergency Department leading to a decreased mortality in ICU - the Critical Care Cascade
Patients with sepsis, severe sepsis and/or septic shock are at increased risk of death and organ dysfunction.
While morbidity and mortality of patients with severe traumatic injury, acute myocardial infarction or stroke have been significantly reduced during recent years by the implementation of well-coordinated...
Infection/sepsis
Glucose
Point-of-care testing
Lactate
Hemoglobins
Article
April 2011
Use of tri-sodium citrate in hemodialysis
Hemodialysis and related treatments for those with failing kidneys all involve blood flow through a circuit outside the body. This extracorporeal circuit - the dialysis machine and its connections from and back to the body - is a non-physiological, pro-coagulant environment.
To counter the tendency for patients'...
Point-of-care testing
Electrolytes
Blood gases/acid-base
Creatinine/urea
Kidneys/fluids
Article
April 2011
Optimizing accuracy and precision for point-of-care tests
Point-of-care testing sites continue to increase in number due to the availability of easy-to-use devices that make it possible to provide test results very quickly relative to the central laboratory services. There is, however, mixed review regarding the accuracy and reliability of POCT results for patient care. It...
Point-of-care testing
Preanalytical phase
Quality assurance
Glucose
Hemoglobins
Lactate
Troponins
Article
January 2011
Critical values in laboratory medicine
The process of patient sample testing, whether performed in the clinical laboratory or at the point of care, is the sum of three distinct phases. The first is the preanalytical phase, which includes test selection as well as sample collection and handling.
The second is the analytical or measuring phase that...
Bilirubin
Electrolytes
Point-of-care testing
Blood gases/acid-base
Glucose
Lactate
Creatinine/urea
Hemoglobins
Kidneys/fluids
Article
January 2011
Moving the Laboratory into the Wards
As healthcare seeks to provide better care with fewer resources, Point-of-Care Testing steps in to move key diagnostic or screening tests to the patient’s bedside. The results can have a significant impact on a patient outcome and operational costs.
Blood gases/acid-base
Process optimization
Glucose
Hemoglobins
Creatinine/urea
Natriuretic peptide
Article
October 2010
D-dimer: Past, present, and future
The following is a copy of an article from Nursing 2007, Fall 2007 Volume 37 Number 8 - Supplement: ED Insider, Pages 14 - 16
The D-dimer level is a measure of clot formation and lysis that results from the degradation of cross-linked fibrin. Widely used as an indicator for the presence of disseminated intravascular ...
Coagulation/fibrinolysis
D-dimer
Article
October 2010
"Permissive hypercapnia" finding its place in clinical care
Over the years, as clinicians have learned how to utilize it, permissive hypercapnia has been finding a place in healthcare. However, it is important to bear in mind that numbers do not tell the entire story.
It is imperative to understand the entire clinical picture before you act. For example, an acidic pH of 7.21...
Blood gases/acid-base
Point-of-care testing
Kidneys/fluids
Article
October 2010
Creatinine measurement in the radiology department 2
Clinical laboratory measurement of serum/plasma creatinine concentration has been used to assess patient kidney function for well over 50 years.
With the incorporation of creatinine analyses to blood gas and other point-of-care platforms the test is now available outside the laboratory, at the bedside and in the...
Point-of-care testing
Glucose
Creatinine/urea
Article
October 2010
Significant figures
The appropriate number of significant figures is important in order to have a meaningful level of resolving power when reporting analytical concentrations. Various methods or criteria can be used when estimating how many significant figures are needed. In most cases three significant figures (two true plus one...
Information management
D-dimer
Troponins