Articles by J. M. Lorenz
Showing articles by "J. M. Lorenz"
Article
June 2001
Establishment of "metrological traceability" for quality control materials and calibrators
The concept of “metrological traceability” is important when establishing comparable clinical decision limits for a measured analyte at different hospitals within one country and in different countries.
This can only be achieved if all instrument manufacturers establish the performance characteristics of their...
Kidneys/fluids
Quality assurance
Article
May 2001
Quality planning and control strategies
What quality is being controlled in laboratories today? The definition of a quality requirement for each laboratory test is the starting point of quantitative quality management.
Different types of requirements may be used as long as there are appropriate quality-planning models for translating those requirements...
Quality assurance
Article
May 2001
Biological variation and quality for POCT
The results of laboratory tests are used in many clinical settings. In the main, results obtained in point-of-care testing (POCT) are used either in monitoring or in diagnosis. Analytical quality does affect outcomes in these clinical situations.
Numerical estimates of the quality required for laboratory tests to...
Quality assurance
Article
May 2001
Quality control of multi-profile blood gas testing
Whether performed by one "traditional" or several "point-of-care" devices, all Multi-Profile Blood Gas (MPBG) results must be accurate and precise if they are to be effective in managing critically ill patients.
Optimal analytical quality control of multi-profile blood gas analysis requires a good quality assurance...
Quality assurance
Article
November 2000
Myocardinal oxygen extraction after two months of adaptation to high altitude
Two months of acclimatization to high altitude leads to an adaptation of the aerobic capacity of the myocardium, characterized by an increased ability to extract O2 from the coronary vascular bed. An increased mitochondrial volume and activity of oxidative enzymes or improved diffusion conditions could be involved.
Point-of-care testing
Blood gases/acid-base
Lactate
Hemoglobins
Article
April 2000
Measurement of transcutaneous oxygen tension in patients with diabetic foot complications
Examination of peripheral pulses and peripheral blood pressures are commonly used methods for investigation of macrocirculation. However, falsely elevated peripheral blood pressures may complicate the accurate prediction of ulcer healing in diabetic patients. Because tcpO2 also measures the nutritive skin capillary...
Blood gases/acid-base
Article
November 1999
Management of point-of-care testing
Point-of-care testing (POCT) is a delivery option for performing laboratory testing closer to the patient. Due to increasing healthcare pressures for faster turnaround of laboratory results and the development of a broader menu of testing devices, POCT is growing in popularity. Devices today are more portable,...
Point-of-care testing
Glucose
Hemoglobins
Article
May 1999
Carbon monoxide intoxication - diagnosis and treat
The effects of carbon monoxide poisoning have been found to be greatly alleviated, or in some cases eliminated, through the use of hyperbaric oxygen therapy. This paper discusses the pathophysiology of carbon monoxide intoxication and presents an overview of its treatment.
Blood gases/acid-base
Hemoglobins
Article
May 1999
Application of hemoglobin derivatives in STAT analysis
Our ability to assess the oxygenation status in critical care with a high degree of accuracy has improved as a result of recent developments in optical technology.
The determination of the oxygenation status, however, remains a complex issue due to its multifaceted nature. This review discusses the definitions,...
Blood gases/acid-base
Glucose
Lactate
Hemoglobins
Article
December 1998
The current status of transcutaneous blood gas analysis and monitoring*
The possibility of continuously monitoring arterial blood oxygen and carbon dioxide using heated surface electrodes on human skin was discovered in the early 1970s and made commercially available by 1976.
These devices were applied initially to premature infants in an effort to reduce the incidence of blindness due...
Blood gases/acid-base
Neonatology
Lactate