Article
September 2004
Quality assurance of the preanalytical phase - complying with ISO 15189:2003
A specimen for clinical laboratory testing must be properly collected from the correct patient at the correct time with proper patient preparation, and the right test must be performed for answering the right question.
Quality in the preanalytical phase of laboratory activity can be assured by implementing a quality...
Quality assurance
Preanalytical phase
Article
September 2004
Hematocrit - a review of different analytical methods
To assess anemia and reduced oxygen-carrying
capacity, a measurement of hematocrit and/or hemoglobin is
performed. Whether hemoglobin or hematocrit is preferred
depends on different needs and is often determined by
tradition.
Both hematocrit and hemoglobin are important
hematology parameters for diagnosing...
Preanalytical phase
Quality assurance
Hemoglobins
Kidneys/fluids
Article
July 2004
The heart of the matter
Blood gas analysis at the point of care plays an important role during and after an open-heart surgery. acutecaretesting.org recently talked to Prof. Knut Kleesiek, MD, Director of the Institute for Laboratory and Transfusion Medicine of the Heart and Diabetes Center North Rhine-Westphalia in Germany, to find out more ...
Point-of-care testing
Blood gases/acid-base
Glucose
Hemoglobins
Lactate
Article
July 2004
Useful tips to avoid preanalytical errors in blood gas testing: neonatal total bilirubin
50-75 % of all newborns develop jaundice during their first week of life [1,2,3]. The decision behind which treatment is necessary and when it should be initiated is based upon a measurement of the concentration of total bilirubin (ctBil) in serum, plasma or whole blood.
It is therefore obvious that it is important...
Quality assurance
Bilirubin
Preanalytical phase
Hemoglobins
Blood gases/acid-base
Article
July 2004
Effective POCT: the need for a broader perspective
Optimizing all the steps in the testing cycle is as crucial to the success of point-of-care testing (POCT) as the measurement process itself. The complete POCT process or testing cycle is a complex series of events that involve many parties in any organization.
Consultation with all the people concerned is vital and ...
Point-of-care testing
Glucose
Article
June 2004
Accreditation of POCT facilities
Point-of-care testing (POCT) is one of the most rapidly
growing areas within laboratory medicine. The need for POCT has
developed because in many cases the central laboratory has been
unable to meet the expectations of clinical users, particularly
with respect to turnaround time.
It is widely recognized that...
Point-of-care testing
Quality assurance
Glucose
Article
April 2004
Setting the record straight on shunt
The understanding and management of ventilation-perfusion (V/Q) relationships represents a cornerstone of intensive care unit (ICU) patient management.
The physiologic shunt calculation can reliably reflect the degree of gas exchange attributable to intrapulmonary disease or intracardiac shunting regardless of other ...
Blood gases/acid-base
Hemoglobins
Article
April 2004
Crossing your Ts in POCT: training and technology
Every POCT program today struggles with providing a solid program that is error free. Each program must be designed to fit the needs of the organization, so having the right people in key positions is important.
Additionally, training and competency programs are necessary so that each POCT operator understands the...
Point-of-care testing
Quality assurance
Article
April 2004
The practice of cord gas analysis in United Kingdom and Germany
Apgar scores and umbilical artery pH have traditionally been used as objective measures of neonatal asphyxia. According to the literature, the practice of cord gas analysis varies greatly both between and within countries - whether analysis is performed, whether it is routine at all births and why it is performed...
Blood gases/acid-base
Neonatology
Glucose
Article
April 2004
Multiprofile blood gas method comparison studies
Numerous method comparison studies of blood gas analyzer methods have been published in the literature; unfortunately, several studies show flaws in one or several aspects of experimental design, execution, statistical analysis or interpretation of results. The most common flaw seems to be an inability to separate...
Preanalytical phase
Point-of-care testing
Quality assurance