Printed from acutecaretesting.org
Articles by John T. Philbrick
Showing articles by "John T. Philbrick"
Article
September 2002
A six sigma primer desc.
"Six Sigma" is the latest trend in quality management and is being widely implemented in business and industry today.
Six Sigma represents an evolution of Total Quality Management (TQM), providing a more quantitative framework for evaluating process performance and clearer goals for process improvement. The...
Quality assurance
Article
May 2002
Transcutaneous carbon dioxide monitoring: Applications in the operating room
The intraoperative monitoring of the partial pressure of carbon dioxide in arterial blood (pCO2) is used to assess the adequacy of ventilation and guide clinical interventions.
Although end-tidal CO2 monitoring remains the most frequently used non-invasive technology in the intraoperative setting to provide a...
Blood gases/acid-base
Neonatology
Kidneys/fluids
Article
May 2002
STAT testing in the neonate
Babies are not small adults! The potential for abnormal adaptation to life outside of the womb, changes in physiology, and a myriad of possible life-threatening clinical conditions requires an understanding of the laboratory tests needed to support these infants.
To effectively handle the unique needs of these...
Point-of-care testing
Neonatology
Glucose
Creatinine/urea
Hemoglobins
Article
May 2002
Fetal capillary blood pH (fetal blood sampling)
Electronic fetal monitoring (EFM) during labor has been performed for 40 years. However, the specificity in diagnosing asphyxia is still insufficient. The combination of EFM and fetal scalp-blood sampling was introduced shortly after the introduction of EFM.
Although this monitoring ensures a better sensitivity and...
Blood gases/acid-base
Neonatology
Preanalytical phase
Article
June 2001
Establishment of "metrological traceability" for quality control materials and calibrators
The concept of “metrological traceability” is important when establishing comparable clinical decision limits for a measured analyte at different hospitals within one country and in different countries.
This can only be achieved if all instrument manufacturers establish the performance characteristics of their...
Kidneys/fluids
Quality assurance
Article
May 2001
Quality in the small laboratory
How do small labs cope with the demands of modern quality assurance?
In this interview, Ruth Lock, head of the laboratory of the Anesthesiology and Intensive Care Dept. of the Copenhagen County Hospital in Glostrup, Denmark, tells how her lab keeps up with demands with the help of training and quality control.
Quality assurance
Hemoglobins
Article
May 2001
The quality of diagnostic samples
While analytical quality standards seem well established, there has been a paucity in the development of such standards for the preanalytical phase.
Technical recommendations regarding sampling, transport, and identification have been developed in national (NCCLS, DIN) and international (IFCC, ISO) consensus...
Preanalytical phase
Quality assurance
Glucose
Lactate
Hemoglobins
Article
May 2001
Quality planning and control strategies
What quality is being controlled in laboratories today? The definition of a quality requirement for each laboratory test is the starting point of quantitative quality management.
Different types of requirements may be used as long as there are appropriate quality-planning models for translating those requirements...
Quality assurance
Article
December 2000
Blood gases, acid-base balance, muscle mass and exercise capacity at the upper tolerable limit for humans of acute and chronic hypoxia
An altitude of 5,000 meters above sea level or just above is just about what humans can bear - be it during an acute ascent or for permanent living. This study describes how bodily functions of crucial importance to survival at high altitude adjust after abrupt exposure to severe hypoxia.
Blood gases/acid-base
Glucose
Article
November 2000
Myocardinal oxygen extraction after two months of adaptation to high altitude
Two months of acclimatization to high altitude leads to an adaptation of the aerobic capacity of the myocardium, characterized by an increased ability to extract O2 from the coronary vascular bed. An increased mitochondrial volume and activity of oxidative enzymes or improved diffusion conditions could be involved.
Point-of-care testing
Blood gases/acid-base
Lactate
Hemoglobins
