Showing articles by "K. Wiener"
Article
April 2004
The practice of cord gas analysis in United Kingdom and Germany
Apgar scores and umbilical artery pH have traditionally been used as objective measures of neonatal asphyxia. According to the literature, the practice of cord gas analysis varies greatly both between and within countries - whether analysis is performed, whether it is routine at all births and why it is performed...
Blood gases/acid-base
Neonatology
Glucose
Article
April 2004
The merit of routine cord blood measurement at birth
Cord blood ph measurement at birth, using relatively simple and non-invasive methods, provides obstetricians and perinatologists with an objective and sensitive measure for the condition of the infant during the final stage of birth.
As long as certain criteria are observed, the reported values are reliable. Routine ...
Neonatology
Blood gases/acid-base
Lactate
Article
January 2004
Useful tips to avoid preanalytical errors in blood gas testing: metabolites
Measurement of glucose and lactate after 30 minutes of storage at room temperature can give deviating results of up to 5 % [1,2] and 29 % of the reference value [3] respectively [1,4], due to in vitro glycolysis
Glucose and lactate are both important parameters in the surveillance of patients in critical care...
Preanalytical phase
Glucose
Quality assurance
Lactate
Blood gases/acid-base
Article
January 2004
Transcutaneous monitoring of pO2 and pCO2 in neonates - a blessing or a burden?
Monitoring of blood gases is essential in neonatal intensive care. Traditionally arterial samples have been considered the gold standard, but in critically ill neonates physiological changes can happen within minutes to a degree endangering the newborn.
Clinicians can therefore not rely solely on intermittent...
Neonatology
Article
October 2003
Proficiency testing versus QC-data-comparison programs
Evaluation of the quality of the total testing process of a laboratory is very important to assure that the results supplied by the laboratory are correct and can be used for decisions by the personnel ordering the tests. In this paper Proficiency Testing (PT) or External Quality Assessment (EQA) is described.
PT is...
Quality assurance
Article
October 2003
Useful tips to avoid preanalytical errors in blood gas testing: electrolytes
Preanalytical errors are said to be the reason for up to 75 % [1] of all errors in laboratory medicine. The diagnostic consequences depend on the magnitude of the preanalytical error.
In worst case, these errors may lead to mistreatment of patients; in all cases, these errors are an extra workload for the hospital...
Preanalytical phase
Electrolytes
Quality assurance
Glucose
Hemoglobins
Blood gases/acid-base
Article
September 2003
Principles and problems of blood glucose measurement
Although blood glucose measurement is commonly performed, the use of a whole-blood sample introduces complications and compromise in terms of the assay principle, the method of calibration and the expression of results.
Most point-of-care systems are calibrated against a method chosen by the manufacturer for...
Glucose
Preanalytical phase
Article
Article
July 2003
All about base excess – to BE or not to BE
In 1948, Singer and Hastings introduced the concept of buffer base (BB). The change in BB from "normal" was called deltaBB (ΔBB). This change in BB was an expression of the non-respiratory (metabolic) component of an acid-base disturbance. This was the first approximation to base excess.
In the 1950s, Astrup and...
Blood gases/acid-base
Hemoglobins
Article
July 2003
The EU IVD Directive (98/79 EC) - a user’s point of view
The Directive is a complex and detailed document and in the following the author focuses on some of the items that are particularly important for the user to be aware of.
Most of the rules will apply to the manufacturers and the public and the users will take advantage of the rulings if they become aware of their...
Quality assurance
Glucose