Printed from acutecaretesting.org
Articles by K. H. B. Madsen
Showing articles by "K. H. B. Madsen"
Article
July 2006
History of GFR and practical issues related to implementation
Although creatinine clearance has been the mainstay for
estimating glomerular filtration rate (GFR) in laboratories for the
past half-century, prediction equations based on serum creatinine
and other routine serum analytes are now available which enable
reporting of a calculated GFR using the Modification of Diet in...
Glucose
Article
July 2006
Doctor testing and competency for POCT
As point-of-care testing (POCT) continues to expand in
the hospital environment, the desire of physicians to participate
in the performance of testing may increase. This article discusses
the required competencies for a physician who wishes to be involved
in laboratory testing and some practical considerations for...
Information management
Point-of-care testing
Article
July 2006
Using the new NACB Practice Guidelines to enhance POCT
The National Academy of Clinical Biochemistry has
developed a Laboratory Medicine Practice Guideline for
point-of-care testing (POCT). This POCT guideline systematically
reviews the scientific literature linking POCT to patient outcome
and makes recommendations for the optimal use of POCT in patient
care.
This...
Point-of-care testing
Quality assurance
Article
April 2006
Reporting calculated GFR from serum creatinine
The National Kidney Disease Education Program (NKDEP)
Laboratory Working Group reviewed problems related to serum
creatinine measurement for estimating glomerular filtration rate
(GFR) and prepared recommendations to standardize and improve
creatinine measurement.
The NKDEP recommends using the estimating equation...
Information management
Glucose
Creatinine/urea
Kidneys/fluids
Article
April 2006
I found the gap… it’s in the basement!
This is the second in a series of articles. The first
essay, “Quality control in theory and practice – a gap analysis”,
published here in January 2006 raised the question:
Has “the system” given front-line laboratory workers the
knowledge and tools they need to make quality control decisions
wisely – or is there a...
Quality assurance
Article
April 2006
Red-cell transfusion – risks and benefits - part 2 of 2
This is the second of two articles about the risks and benefits of red-cell transfusion directed at healthcare professionals without any particular transfusion expertise.
The focus of the first article was the risks and the extensive measures taken to minimize those risks.
For this second article, attention turns to...
Blood gases/acid-base
Hemoglobins
Kidneys/fluids
Article
January 2006
Quality control in theory and practice – a gap analysis
Millions of times every day, in a myriad of distinctive
laboratories around this globe, front-line workers make the final
decision on the quality of results they report.
If they decide the
quality is “OK”, patient results are released to impact clinical
decisions, and proficiency values reflect the overall ability...
Quality assurance
Article
January 2006
Red-cell transfusion – risks and benefits - part 1 of 2
Although often of life-saving benefit, transfusion of
donated red cells is associated with considerable potential risk
for the recipient patient.
This article, directed at healthcare
professionals without any particular transfusion expertise,
outlines these risks and the measures taken to minimize them.
Particular...
Blood gases/acid-base
Preanalytical phase
Hemoglobins
Neonatology
Article
October 2005
Patient safety: tested tools for error reduction
Laboratorians need to take ownership of errors,
identifying, analyzing and reducing them, thereby increasing
patient safety.
A Client Services Department, customer care
representatives, a service improvement coordinator, “morning
report”, electronic error tracking and reporting mechanisms,
point-of-care support...
Point-of-care testing
Information management
Process optimization
Glucose
D-dimer
Article
October 2005
Arterial blood collection: sampling and storage - part 2 of 2
The collection of arterial specimens with glass syringes
and immediate storage in iced water was the accepted industry
standard for many years. Practice has changed over the past several
years to blood gas sample collection in plastic syringes, likely
due to the cost, safety and convenience of plastic.
This change
...
Quality assurance
Blood gases/acid-base
