Printed from acutecaretesting.org
Articles by Per Simonsson
Showing articles by "Per Simonsson"
Article
July 2014
Point-of-care testing in the emergency department with emphasis on chest pain patients
The management at the emergency department of patients presenting with symptoms of chest pain and/or acute dyspnea accounts for a substantial proportion of emergency care resources.
In the work-up of these patients the blood measurements of cardiac troponins and brain natriuretic peptides are recommended by current...
D-dimer
Troponins
Natriuretic peptide
Article
October 2013
Age-adjustment of the D-dimer cut-off value to improve the exclusion of thromboembolic events in older patients
With increasing age, an unspecific rise of fibrin degradation product in blood is observed. Thus, the D-dimer test to rule out thromboembolic events has a high false positive rate in elderly patients.
In 2010, Douma et al introduced a formula to adjust D-dimer cut-off values for age in outpatients >50 years: Age ×...
Coagulation/fibrinolysis
D-dimer
Article
July 2013
A regional program for POCT service to emergency departments – results and remaining challenges
In a regional top-management decision, our laboratory was given the mission to control and quality assure all POCT activities in a regional network of 10 hospitals with emergency units. Based on previous work, new region-wide recommendations, procurements, IT connectivity, services, training, accreditation (ISO...
Process optimization
Point-of-care testing
Blood gases/acid-base
Glucose
Lactate
Creatinine/urea
D-dimer
CRP
Article
October 2010
Significant figures
The appropriate number of significant figures is important in order to have a meaningful level of resolving power when reporting analytical concentrations. Various methods or criteria can be used when estimating how many significant figures are needed. In most cases three significant figures (two true plus one...
Information management
D-dimer
Troponins
Article
October 2009
Low troponin I concentrations and clinical decision making
Troponin values above the 99th percentile and increasing/falling values found by serial testing in addition to signs and symptoms of myocardial ischemia means AMI.
Low troponin values, near or below the 99th percentile, can be used for prognosis. Highest hazard ratios were found when using the 90th percentile,...
Cardiac markers
Troponins
Natriuretic peptide
Article
June 2005
Reducing sharps injury risk in intensive care
Five years of data on percutaneous injuries (PIs) from the EPINet multi-hospital sharps injury database at the University of Virginia were analyzed to understand exposure risks faced by personnel in intensive care/critical care settings.
Of 687 PIs in intensive care units (ICUs), nurses had the highest proportion of...
Quality assurance
Blood gases/acid-base
Preanalytical phase
Article
April 2004
Multiprofile blood gas method comparison studies
Numerous method comparison studies of blood gas analyzer methods have been published in the literature; unfortunately, several studies show flaws in one or several aspects of experimental design, execution, statistical analysis or interpretation of results. The most common flaw seems to be an inability to separate...
Preanalytical phase
Point-of-care testing
Quality assurance
Article
April 2004
Setting the record straight on shunt
The understanding and management of ventilation-perfusion (V/Q) relationships represents a cornerstone of intensive care unit (ICU) patient management.
The physiologic shunt calculation can reliably reflect the degree of gas exchange attributable to intrapulmonary disease or intracardiac shunting regardless of other ...
Blood gases/acid-base
Hemoglobins
Article
May 2001
Quality control of multi-profile blood gas testing
Whether performed by one "traditional" or several "point-of-care" devices, all Multi-Profile Blood Gas (MPBG) results must be accurate and precise if they are to be effective in managing critically ill patients.
Optimal analytical quality control of multi-profile blood gas analysis requires a good quality assurance...
Quality assurance
