Article
February 2003
What is p50
p50 is a shorthand representation of hemoglobin-oxygen affinity. A lower p50 is protective in ambient hypoxemia, whereas increasing the p50 should be beneficial in hypoxia due to lung disease, anemia, and tissue ischemia.
Despite encouraging theoretical and experimental data, it is not yet established that...
Blood gases/acid-base
Hemoglobins
Article
December 2002
The use of capability index for running and monitoring quality control
In our laboratory, we have used a combination of assay capability and the Westgard multirules as the basis of our quality control procedures.
We have also used the concept of six sigma as the criterion for performance acceptability, which has allowed the identification of problem analytes and instituted improvements...
Quality assurance
Article
December 2002
Practical planning considerations when interfacing
Attention to how data are handled by different groups in a hospital is important when interfacing a point-of-care testing system.
Consideration of existing data handling practices and future data evaluation needs - before, during, and after installation - and careful planning in cooperation with each hospital...
Information management
Point-of-care testing
Glucose
Article
November 2002
The role of training, competency assessment, and continuing education
In a 1999 study, the US Institute of Medicine (IOM) concluded that 44,000 to 98,000 hospitalized Americans die each year from preventable medical errors.
While the number of serious medical errors attributable to point of care (point-of-care testing, POCT) is not known, the testing environment (patient bedside) and...
Process optimization
Point-of-care testing
Glucose
Article
November 2002
Transcutaneous carbon dioxide/oxygen monitoring in critical care medicine: just for children?
Transcutaneous non-invasive monitoring technology has been around for more than thirty years. Throughout this period of time, transcutaneous monitoring has been closely linked to the care of neonates.
However, recent studies suggest that transcutaneous technology may work just as well in older children and adults....
Neonatology
Article
September 2002
The invention and development of the blood gas analysis apparatus
John Severinghaus, who recently turned 80, is one of the pioneers in the field of blood gas. To celebrate his birthday, bloodgas.org has asked him to look back on the first developments leading to the modern blood gas analyzers.
The following article has also been published in Anesthesiology, The Journal of the...
Point-of-care testing
Blood gases/acid-base
Glucose
Lactate
Hemoglobins
Article
September 2002
Understanding the different values in electrolyte measurements
The measurement of the electrolytes in blood is one of the most frequently performed measurements as the electrolytes are of major physiological importance for numerous functions of the body.
Analysis of electrolytes such as sodium and potassium are performed in the traditional clinical chemistry laboratory, but are...
Quality assurance
Electrolytes
Preanalytical phase
Article
September 2002
A six sigma primer desc.
"Six Sigma" is the latest trend in quality management and is being widely implemented in business and industry today.
Six Sigma represents an evolution of Total Quality Management (TQM), providing a more quantitative framework for evaluating process performance and clearer goals for process improvement. The...
Quality assurance
Article
September 2002
Evidence-based medicine and point-of-care testing
Point-of-care testing provides rapid laboratory diagnostics close to the site of care. Quality assurance of POCT, however, requires significant resources that should be matched with improved patient outcome and benefit. Application of evidence-based medicine to POCT can critically assess the medical effectiveness of...
Point-of-care testing
Article
September 2002
U.S. quality assurance regulations for decentralized testing
In the U.S. all testing, including decentralized testing, is regulated according to the Clinical Laboratory Improvement Amendments of 1988 (CLIA'88). Congress passed CLIA'88 to ensure accurate, reliable, and timely test results regardless of test site.
These quality control, quality assurance, and proficiency tesing...
Quality assurance
Information management