Printed from acutecaretesting.org
Articles by S. W. Rasmussen
Showing articles by "S. W. Rasmussen"
Article
April 2011
Use of tri-sodium citrate in hemodialysis
Hemodialysis and related treatments for those with failing kidneys all involve blood flow through a circuit outside the body. This extracorporeal circuit - the dialysis machine and its connections from and back to the body - is a non-physiological, pro-coagulant environment.
To counter the tendency for patients'...
Point-of-care testing
Electrolytes
Blood gases/acid-base
Creatinine/urea
Kidneys/fluids
Article
January 2011
ROC curves – what are they and how are they used?
ROC curves are frequently used to show in a graphical way the connection/trade-off between clinical sensitivity and specificity for every possible cut-off for a test or a combination of tests. In addition the area under the ROC curve gives an idea about the benefit of using the test(s) in question.
ROC curves are...
Information management
Article
January 2011
Critical values in laboratory medicine
The process of patient sample testing, whether performed in the clinical laboratory or at the point of care, is the sum of three distinct phases. The first is the preanalytical phase, which includes test selection as well as sample collection and handling.
The second is the analytical or measuring phase that...
Bilirubin
Electrolytes
Point-of-care testing
Blood gases/acid-base
Glucose
Lactate
Creatinine/urea
Hemoglobins
Kidneys/fluids
Article
October 2010
D-dimer: Past, present, and future
The following is a copy of an article from Nursing 2007, Fall 2007 Volume 37 Number 8 - Supplement: ED Insider, Pages 14 - 16
The D-dimer level is a measure of clot formation and lysis that results from the degradation of cross-linked fibrin. Widely used as an indicator for the presence of disseminated intravascular ...
Coagulation/fibrinolysis
D-dimer
Article
October 2010
Creatinine measurement in the radiology department 2
Clinical laboratory measurement of serum/plasma creatinine concentration has been used to assess patient kidney function for well over 50 years.
With the incorporation of creatinine analyses to blood gas and other point-of-care platforms the test is now available outside the laboratory, at the bedside and in the...
Point-of-care testing
Glucose
Creatinine/urea
Article
July 2010
Cardiac biomarkers for acute coronary syndrome and ongoing myocardial damage in heart failure
The growing role of cardiac markers has
been elucidated in patients with acute coronary syndrome, heart
failure and other cardiovascular diseases.
The markers can be cytosolic like
heart-type fatty-acid-binding protein (H-FABP) and creatine kinase
MB (CKMB), myofibrillary like troponin T (TnT) and cardio-endocrine...
Cardiac markers
Troponins
Natriuretic peptide
Article
July 2010
FAQ concerning the acid-base status of the blood
Some of the frequently asked questions are: Should we use BE (base excess) or SID (strong ion difference) as a measure of a metabolic acid-base disturbance? Is there any difference between BB (buffer base) and SID? Should we use SBE (standard base excess), i.e. BE referring to the expanded extracellular fluid or...
Blood gases/acid-base
Point-of-care testing
Glucose
Lactate
Creatinine/urea
Hemoglobins
Article
July 2010
Diagnosis of DVT with D-dimer testing and the Wells score
The following is a copy of an article from Evidence-Based Practice, 2007; 10(12):1-2.
Venous thromboembolism refers to a spectrum of disease that includes both pulmonary embolus and deep-venous thrombosis (DVT).
More than 250,000 people in the United States are diagnosed annually with venous thromboembolic disease;...
Coagulation/fibrinolysis
D-dimer
Article
April 2010
Benefit of using a D-dimer assay with a high clinical specificity
CONTEXT: Sensitive D-dimer assays have been developed to exclude the diagnosis of deep vein thrombosis (DVT) and have exhibited great success when used in conjunction with a diagnostic algorithm, including pretest probability scoring and a compression ultrasound (CUS).
Improving specificity of D-dimer assays would...
Coagulation/fibrinolysis
D-dimer
Article
April 2010
Creatinine measurement in the radiology department 1
Clinical laboratory measurement of serum/plasma creatinine concentration has been used to assess patient kidney function for well over 50 years. With incorporation of creatinine analyses to blood gas and other point-of-care platforms the test is now available outside the laboratory, at the bedside and in the clinic.
...
Point-of-care testing
Creatinine/urea
Kidneys/fluids
