Articles by C. Schuerch
Showing articles by "C. Schuerch"
Article
June 2009
D-dimer as a rule-out test for deep venous thrombosis: Gold standards and bias in negative predictive value
Recent studies of D-dimer as a “rule-out” test for deep venous thrombosis (DVT) frequently have used duplex ultrasound rather than venography as the gold standard.
Because duplex ultrasound has limited ability to image the calf veins, there is potential for ultrasound studies to classify patients with calf DVT as...
Coagulation/fibrinolysis
Hemoglobins
D-dimer
Article
April 2009
Reference intervals (2) - some practical considerations
This is the second of two articles focusing on the reference interval, the most widely used tool for interpretation of patient test results.
The first [1] was an introduction to the theoretical concepts that underpin the significance, construction and use of reference intervals. Here consideration is given to the...
Quality assurance
Information management
Point-of-care testing
Hemoglobins
Article
January 2009
C-reactive protein and procalcitonin in the assessment of infection response to antibiotic therapy
Definite diagnosis of infection requires microbiological
documentation; however, the identification of a specific etiology
is frequently missing. In addition, bacterial cultures require at
least 24-48 hours for a final result, which is too long for a
decision to start antibiotics.
Currently, the evaluation of the...
Infection/sepsis
Article
January 2009
An introduction to reference intervals (1) - some theoretical considerations
The population-based reference interval is the most
widely used tool for interpretation of individual patient
laboratory test results. The clinical value of those results
depend crucially on the reference intervals with which they are
compared, and all efforts directed at ensuring analytically
precise and accurate...
Blood gases/acid-base
Point-of-care testing
Process optimization
Hemoglobins
Article
October 2008
Parameters that reflect the carbon dioxide content of blood
Updated with new information from a 2008 article! Health demands that despite quite significant variation in its rate of production, the amount of carbon dioxide in blood is maintained within well-defined narrow limits.
The homeostatic mechanisms that maintain the normal content of carbon dioxide in blood are...
Blood gases/acid-base
Creatinine/urea
Hemoglobins
Article
October 2008
Iatrogenic anemia - a downside of blood testing
All clinical procedures and treatments are associated with potential adverse effects of greater or lesser significance.
The undisputed value of blood testing for both diagnosis and monitoring of disease is tempered by the recognition that repeated blood sampling can result in blood loss of sufficient magnitude to...
Preanalytical phase
Hemoglobins
Article
July 2008
Point of care connectivity
With the use of a new Data Management System (DMS) software program [1], the majority of Point Of Care Testing (POCT) equipment throughout the Waikato District Health Board region has been connected to the Laboratory Information System (LIS) and the Hospital Information System (HIS).
Prior to the new DMS, viewing...
Point-of-care testing
Blood gases/acid-base
Information management
Process optimization
Glucose
Troponins
Article
July 2008
Capillary blood gases - to arterialize or not
The ‘gold standard’ sample for blood gas analysis is arterial blood obtained via an indwelling arterial catheter or by arterial puncture. For a number of reasons capillary blood is an attractive substitute sample that is routinely used in some clinical settings.
The purpose of this article is to examine the evidence ...
Neonatology
Glucose
Preanalytical phase
Article
January 2008
Measurement of circulating glucose: The problem of inconsistent sample and methodology
There are few medical diagnoses that depend solely on the result of a single blood test, but diabetes mellitus, which is defined by concentration of circulating glucose, is one that does.
Quite apart from its long established role in diagnosis as well as life-long monitoring of diabetes, measurement of circulating...
Glucose
Hemoglobins
Preanalytical phase
Article
January 2008
Point-of-care testing; systems re-engineering of healthcare provision to reduce errors, and improve outcomes
Modern analytical devices for testing biological fluids, such as blood, have now developed a sophistication that ensures the quality of the analytical result is capable of matching that achieved in the central laboratory.
Complementary developments are focused on reducing operator-related and connectivity-related...
Point-of-care testing
Information management
Process optimization